Description
PC 3000 Multi Parametric Monitor:
- 7'' high resolution TFT color display, with 5 channel display (various parameter display modes available)
- Standard parameters: ECG, RESP, SpO2, NIBP, 2-TEMP, PR;
- Arrhythmia analysis and ST segment analysis
- Store up to 800 sets of data and 24 hours of ECG traces
- 480 hour graphic and tubular trend for all parameters
- Display shows 7 ECG channels simultaneously
- Protection against interference from defibrillation/electrosurgery
- Adult/pediatric measurement mode
- Visual and audible alarms
Technical features:
NIBP monitoring
- Measurement method: Automatic measurement by oscillation method
- Cuff inflation time: - Initial cuff inflation pressure: Adult and pediatric model: 180mmHg
- Overpressure protection limit: Adult and pediatric model: 300mmHg
Measuring range
- Systolic blood pressure: Adults and children: 25mmHg – 265mmHg
- Diastolic blood pressure: Adults and children: 12mmHg – 220mmHg
- Mean arterial pressure: Adults and children: 18mmHg – 245mmHg
- Measurement accuracy: Systolic +- 10% Diastolic +- 10% MAP +- 10%
- Measurement modes: Manual, Automatic, STAT
- Automatic measurement: 1-240 min
Intervals: Interval tolerance:
TEMP. monitoring
- Measuring range, accuracy: 15°C – 45°C, +-0.2°C
SpO2 & Pulse Rate Monitoring
- Dual wavelength LED transducer
- SpO2 measurement range 35 %-100%
- Low perfusion capacity 0.4% - 5%
- SpO2 display accuracy: 90%~99% ±2%, 70%~89% ±4%, 40%~69% ±6%
- PR measurement range: 30bpm~250bpm
- PR measurement accuracy: ±2bpm
ECG monitoring
- Heart rate measurement: ± 0.4mVp~ ±3mVp
- Heart rate display range: 20bpm~250bpm
- Display accuracy: ±1% or ± 2 bpm, whichever is greater
- Heart rate delay time alarm: =12s
- Sensitivity selection: Auto, ×1/2, ×1, ×2, ×4 tolerance: =5%
- Speed: 12.5 mm/s, 25mm/s, 50mm/s tolerance: =10%
- ECG noise level: =30µVP-P
- Input ECG current: =0.1µA
- Input impedance: =5MO
- Time constant monitoring mode
- Diagnostic mode
- Response Rate Monitoring Mode
- Diagnostic mode
RESP monitoring
- Measuring range, accuracy: 0rpm~120rpm, ±10%
- RESP alarm range: 0bpm~100bpm
- Alarm tolerance: ±10%
Other technical features
- Power supply: 100~250Vac, 50/60Hz
- Consumption: - 1.2 inch display, color TFT LCD
- Alarm mode Visual-acoustic alarms
- Ethernet network port
- BD/RDM: 1316206
- CND: Z1203020201
- Paraf: 977815481
- ean13: 6941900604186
- GMDN: 33586
Equipment:
1 ECG cable
1 adult SpO2 probe
1 AC power adapter
1 Li-ion battery
1 NIBP cuff
1 Body surface temperature sensor
10 disposable electrodes
1 Power cable
User manual
- 7'' high resolution TFT color display, with 5 channel display (various parameter display modes available)
- Standard parameters: ECG, RESP, SpO2, NIBP, 2-TEMP, PR;
- Arrhythmia analysis and ST segment analysis
- Store up to 800 sets of data and 24 hours of ECG traces
- 480 hour graphic and tubular trend for all parameters
- Display shows 7 ECG channels simultaneously
- Protection against interference from defibrillation/electrosurgery
- Adult/pediatric measurement mode
- Visual and audible alarms
Technical features:
NIBP monitoring
- Measurement method: Automatic measurement by oscillation method
- Cuff inflation time: - Initial cuff inflation pressure: Adult and pediatric model: 180mmHg
- Overpressure protection limit: Adult and pediatric model: 300mmHg
Measuring range
- Systolic blood pressure: Adults and children: 25mmHg – 265mmHg
- Diastolic blood pressure: Adults and children: 12mmHg – 220mmHg
- Mean arterial pressure: Adults and children: 18mmHg – 245mmHg
- Measurement accuracy: Systolic +- 10% Diastolic +- 10% MAP +- 10%
- Measurement modes: Manual, Automatic, STAT
- Automatic measurement: 1-240 min
Intervals: Interval tolerance:
TEMP. monitoring
- Measuring range, accuracy: 15°C – 45°C, +-0.2°C
SpO2 & Pulse Rate Monitoring
- Dual wavelength LED transducer
- SpO2 measurement range 35 %-100%
- Low perfusion capacity 0.4% - 5%
- SpO2 display accuracy: 90%~99% ±2%, 70%~89% ±4%, 40%~69% ±6%
- PR measurement range: 30bpm~250bpm
- PR measurement accuracy: ±2bpm
ECG monitoring
- Heart rate measurement: ± 0.4mVp~ ±3mVp
- Heart rate display range: 20bpm~250bpm
- Display accuracy: ±1% or ± 2 bpm, whichever is greater
- Heart rate delay time alarm: =12s
- Sensitivity selection: Auto, ×1/2, ×1, ×2, ×4 tolerance: =5%
- Speed: 12.5 mm/s, 25mm/s, 50mm/s tolerance: =10%
- ECG noise level: =30µVP-P
- Input ECG current: =0.1µA
- Input impedance: =5MO
- Time constant monitoring mode
- Diagnostic mode
- Response Rate Monitoring Mode
- Diagnostic mode
RESP monitoring
- Measuring range, accuracy: 0rpm~120rpm, ±10%
- RESP alarm range: 0bpm~100bpm
- Alarm tolerance: ±10%
Other technical features
- Power supply: 100~250Vac, 50/60Hz
- Consumption: - 1.2 inch display, color TFT LCD
- Alarm mode Visual-acoustic alarms
- Ethernet network port
- BD/RDM: 1316206
- CND: Z1203020201
- Paraf: 977815481
- ean13: 6941900604186
- GMDN: 33586
Equipment:
1 ECG cable
1 adult SpO2 probe
1 AC power adapter
1 Li-ion battery
1 NIBP cuff
1 Body surface temperature sensor
10 disposable electrodes
1 Power cable
User manual
Data sheet