Taurus Multiparameter Monitor
zoom_out_map
chevron_left chevron_right

Taurus Multiparameter Monitor

€1,695.00 VAT included

€1,614.29 VAT excluded

new_releases Shipping in 15 days.
Secure payments
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
Description

Taurus multi-parameter monitor

Taurus is a bedside patient monitor suitable for use in different critical hospital areas (intensive care, coronary intensive care unit, operating room, etc.).
Designed to respond to the different requests of critical areas of hospitals, it can be integrated with different invasive and non-invasive and advanced added parameter modules, making it a highly versatile device
Taurus allows you to monitor adult, pediatric and neonatal patients by setting alarms and limits based on the type both manually and using MEWS technology
Equipped with a large 12.1 inch color display with touchscreen function INCLUDED, it allows the display of up to eight waveforms as well as numerical values and the selection of 5 display types.
The Taurus monitor allows the detection of the patient's electrocardiogram up to 12 leads (optional), the detection of breathing with the impedance method, guarantees precise and rapid NIBP measurements, allows the measurement of oxygen saturation, allowing the choice between three SpO2 technologies of the best brands currently on the market, finally, it is possible to monitor the Double Skin Temperature with compatible YSI temperature probes. The device is also equipped with software that allows the analysis of the ST segment, arrhythmias and for the calculation of hemodynamic, drug, oxygenation and ventilation values.
The Taurus can be requested configured with optional modules such as: 2/4 channel IBP, C.O. (cardiac output), EtCO2 Sidestream or Mainstream allowing the choice between 3 technologies, MultiGAS with sidestream/mainstream CO2 with or without oxygen detection.
Furthermore, the Taurus can be configured with advanced modules such as the BISx (Aspect) module and the NMT (Organ Tof-Watch) module
The Taurus monitor can also be implemented with the module for rapid tympanic temperature detection (optional), thanks to which it is possible to take body temperature measurements reliably and within seconds.
Wide connectivity for connection to the monitoring center (CMS) with Wired or Wireless connection (Wi-Fi or 3G).
Taurus is an advanced monitor that guarantees absolute quality performance and high safety standards combined with ease of use and intuitiveness that will leave you fully satisfied.

MAIN FEATURES

• 12.1 inch color TFT LCD display with INTEGRATED touchscreen function
• Display of 8 traces and up to 12 ECG leads
• High parameter configurability for different critical hospital areas (ICU, CCU, NICU)
• Optional modules available IBP, C.O., EtCO2, MultiGAS, BIS, NMT
• Complete calculation function (hemodynamic, pharmacological, oxygenation, ventilation)
• Pacemaker detection
• ST and Arrhythmia analysis
• Oxycardiogram (OxyCRGs) screen
• MEWS (Modified Early Warning Score) warning system
• Possibility of Wired or Wireless connection to the monitoring station
• SpO2 pulse tone modulation (Pitch Tone)
• Transport handle with integrated stretcher attachment
• Redisplay of tabular and graphical trends (120 hours)
• Equipped with long-lasting rechargeable Li-ion battery



Technical features:

CLASSIFICATION

Safety Standard: IEC60601-1
Electromagnetic Compatibility: IEC 60601-1-2 Group I class B
Type of protection against electric shock: Class with internal power supply
Electric shock protection level: ECG/NIBP/SpO2/PR/TEMP/RESP: CF (defibrillation test)
Level of protection against fire risks of flammable anesthesia mixtures: unprotected (normal state)
Protection level against damage from water ingress: IPX1
Operation mode: continuous
Device type: Portable
Community directive: 2007/47/EC
Use classification: IIB
Operation mode: continuous
CND: Z12030020202
RDM: 1455233
ENVIRONMENTAL REQUIREMENTS

Operating temperature: 0 – 40°C
Operating humidity: 15 – 85%, non-condensing
Altitude: -500 – 4600m (-1640 – 15092 feet)
Storage temperature: –20 – 60°C
Storage humidity: 10 – 95%, non-condensing
DIET

AC mains electricity

Input voltage: 100-240V
Input current: 1.0-0.5A
Frequency: 50/60Hz
Fuse: T1.6A 250V
Internal battery

Type: lithium (Li-ion)
Nominal tension: d.c. 11.1V
Capacity: 4800mAh
Operating time: about 5 hours
Charging time: about 6 hours (in start-up state or standby mode)
CASING

Dimensions: 310×285×166mm (width×height×depth)
Weight: 4.2 kg (basic configuration)
DISPLAY

Type: Color LCD TFT
Dimensions: 12.1″
Resolution: 800×600 pixels
Traces: 8 waveform display plus numerical parameters
Touch screen: optional
LED INDICATORS

Alarm light: 1 (yellow and red)
Power Indicator (AC): 1 (Green)
Battery level indicator: 1 (green)
AUDIO INDICATOR

Speaker: Provides audible alarm signals (45 ~ 85dB), keypad tones and pulse tone. The acoustic alarm signals comply with EN475 and IEC60601-1-8 standards
PRINTER (optional)

Type: Thermal Point
Horizontal resolution: 32 dots/mm
Vertical resolution: 8 dots/mm
Paper length: 20m
Printing Speed: 12.5mm/s, 25mm/, 50mm/s
Number of printed waveforms: maximum 3 waves
ALARMS

Alarm delay: off or 1s, 2s, 3s, 4s, 5s, 6s, 7s, 8s; depends on the configuration; by default it is equal to 4s.
Break duration: 1min, 2min, 3min, 4min, 5min, 10min, 15min or infinite; depends on the configuration; default is 2min.
COMMANDS

Control knob: 1 knob, which can be operated by rotating clockwise/anticlockwise or by pressing.
Touch screen: optional
Buttons: 5 buttons: power on/off, alarm silencer, wave freeze function, print
CONNECTORS

Power: 1 power connector c.a.
Parameter: ECG, SpO2, NIBP, 2 TEMP
USB interface: 2 ports to update the device
Network: 1 RJ45 connector for standard networks, 100 BASE-TX (Optional)
I/O signal interface: DB9 standard
Equipotentiality: 1 equipotential ground connector
WIRELESS NETWORK (optional)

Reference standards: IEEE 802.11b, Wi-Fi compatible
Frequency range: 2.412 – 2.462 GHz
Safety distance: 10 m (circular area centered on AP with the diameter of 10 m)
Maximum data transfer speed: 11 Mb/s
DATA STORAGE

Trend data: Long trend: 120 hours, minimum resolution of 1 min
Short trend: 1 hour, minimum resolution 1s
Alarm events: 200 parameter alarm events
NIBP Detections: 1000 NIBP groups
ECG (electrocardiogram)

Lead type: 3 leads. (I, II, III); 5 derivatives (I, II, III, aVR, aVL, aVF and V); 12 derivatives (I, II, III, aVR, aVL, aVF, V1-V6) (optional)
Definition of endings: AHA, EURO
Sensitivity selection: 2.5mm/mV (×0.25), 5mm/mV (×0.5), 10mm/mV (×1.0), 20mm/mV (×2.0)
Scanning speed: 6.25mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Bandwidth: diagnosis mode 0.05Hz~100Hz; monitoring mode 0.5Hz~40HzM; Surgery mode 1Hz~20Hz; strong filter mode 5Hz~20Hz
CMRR: >100dB
Noise frequency: 50/60Hz fixed frequency noise can be set to on or off
Differential input impedance: >5MΩ
Shunt voltage (DC): ±400mV
Recovery time after defibrillation: Calibration signal: 1 mV (peak to peak value), accuracy: ±3%
HR (heart rate)

Measurement range: Adult 15 – 300 bpm; Child/Infant 15 – 350 bpm
Resolution: 1bpm
Accuracy: ±1 bpm or ±1%, whichever is greater
Sensitivity: 200 μV (lead II)
Response time to variations in HR: time from 80 to 120 ppm ≤10 sec.; tempo from 80 to 40 bpm ≤10 sec.
Pulse beat

Pulse Indicator: Beat pulses with the following characteristics are marked by the BEAT indicator. Amplitude ±4mv ~ ±700mv; Duration 0.2ms ~ 2.0ms; Rise time 10 us – 100 μs
ST. SEGMENT MEASUREMENT

Measuring range: – 2.0 – +2.0 mV
Accuracy: ±0.02 mV (between – 0.8 ~ +0.8 mV); Undefined (beyond the considered range)
Update period: 10 s
ARRHYTHMIA ANALYSIS

Type: ASISTOLE, VFIB/VTAC, PVC, COUPLE, VT>2, BIGEMINI, TRIPEMINI, ROT, BAT.MANC, TACHI, BRADI, PNC and PNP
BREATH

Measurement technique: Thoracic impedance
Lead: lead I, II (default lead II)
Wave gain: ×0.25, ×0.5, ×1, ×2
Breathing impedance test range: 0.5-5Ω
Baseline impedance range: 500-4000Ω
Scanning speed: 6.25mm/s, 12.5mm/s, 25mm/s
SpO2 NORTHERN 0003 (standard)

Measuring range: 0%~100%
Resolution: 1%
Accuracy: ±2% 70%~100% (adult/pediatric patients, lack of mobility); ±3% 70%~100% (neonatal patients, no mobility); undefined (0% – 69%)
Update rate: 1 s
Importable alarm limits: upper limit 1%~100%; lower limit 0%~99%
PR

Measurement range: 30~254bpm
Resolution: 1%
Accuracy: ±2 bpm (no mobility); ±5 ppm (mobility conditions)
SpO2 NORTHERNn 0039 (optional)

Measuring range: 0%~100%
Resolution: 1%
Accuracy: ±2% 70%~100% (adult/pediatric patients, lack of mobility); ±3% 70%~100% (neonatal patients, no mobility); undefined (0% – 69%)
Update rate: 1 s
Plethysmographic Variability Index (PVI): 0 – 100%
Importable alarm limits: upper limit 1%~100%; lower limit 0%~99%
PR

Measurement range: 30~254bpm
Resolution: 1%
Accuracy: ±2 bpm (no mobility); ±5 ppm (mobility conditions)
SpO2 MASIMO SET (optional)

Measuring range: 0%~100%
Resolution: 1%
Accuracy: ±2% 70%~100% (adult/pediatric patients, lack of mobility); ±3% 70%~100% (neonatal patients, no mobility); undefined (0% – 69%)
Update rate: 1 s
Plethysmographic Variability Index (PVI): 0 – 100%
Perfusion Index (PI): 0.02 – 20%
Importable alarm limits: upper limit 1%~100%; lower limit 0%~99%
PR

Measurement range: 25~240bpm
Resolution: 1%
Accuracy: ±3 bpm (no mobility); ±5 ppm (mobility conditions)
SpO2 NELLCOR (optional)

Measuring range: 0%~100%
Resolution: 1%
Accuracy: ±2% 70%~100% (adult/pediatric patients, lack of mobility); ±3% 70%~100% (neonatal patients, no mobility); undefined (0% – 69%)
Update rate: 1 s
Perfusion Index (PI): 0.02 – 20%
Importable alarm limits: upper limit 1%~100%; lower limit 0%~99%
PR

Measurement range: 20~300bpm
Resolution: 1%
Accuracy: ±3 bpm (20-250); indefinite (251 – 300)
NIBP (non-invasive blood pressure)

Measuring technique: Automatic oscillation
Parameters displayed: Systolic pressure, diastolic pressure and average pressure
Operation modes: Manual, automatic and continuous
Typical measurement time: 70~40s
Measuring range in normal mode (mmHg)
Systemic pressure Diabolic pressure Average pressure
Adult: 40-270 Adult: 10-210 Adult: 20 – 230
Child: 40 – 200 Child: 10 – 150 Child: 20 – 165
Newborn: 40 – 135 Newborn: 10 – 100 Newborn: 20 – 110

Detection accuracy: Maximum error (average value) ±5 mmHg;
Maximum deviation (standard value): 8 mmHg
Resolution: 1mmHg
Detection interval in automatic mode: 1/2/3/4/5/10/15/30/60/90/120/180/240/480 minutes
Overlay protection: Software and Hardware double security protection
Cuff pressure: 70 ~ 280 mmHg
TEMPERATURE

Measuring technique: thermistor
Number of channels: 2 channel
Parameters displayed: T1, T2 and TD
Measuring range: 5~50°C (41~122°F)
Resolution: 0.1°C
Accuracy: ±0.1°C
IBP (invasive pressure) (optional)

Measurement method: invasive blood test
Number of channels: 2 or 4 channels
Pressure cards: ART, PA, CVP, RAP, LAP, ICP, P1 and P2
Measuring range: -50 ~ 300mmHg
Resolution: 1mmHg
Accuracy: ±1% or ±2 mmHg, whichever is greater (not counting sensor error)
Update period: 1 s
C.O. (cardiac output) (optional)• Measurement technique: Thermal dilution• Calculation parameter: CO, hemodynamics• Measuring range: C.O. 0.20~20.00L/MIN; TB 23.0~45.0°C; TI -1.0~27.o°C• Resolution: C.O. 0.01L/MIN; TB & TI 0.1°C• Accuracy: C.O. ±5%; TB & TI ±0.5°C

EtCO2 SIDESTREAM MASIMO PHAISEN Phaisen ISA (optional)

CO2 measuring range: 0 to 150 mmHg – 0 ~ 25 vol%
Accuracy: 0.2% +2% (0 ~ 15 vol%); unspecified (15 ~ 25 vol%)
Start-up time: Response time: Rise time (50ml/min sample flow): ≤200ms
AwRR measurement range: 0 ~ 150 ±1 rpm
EtCO2 MAINSTREAM MASIMO PHAISEN IRMA (optional)

CO2 measuring range: 0 ~ 25 vol%
Accuracy: 0.2% +2% (0 ~ 15 vol%); unspecified (15 ~ 25 vol%)
Start-up time: Response time: Inspiratory rise time (@10 l/min): ≤90ms
AwRR measurement range: 0 ~ 150 ±1 rpm
The specifications of the other EtCO2 technologies are reported in the device user manual. If you wish to have technical information on these modules, please contact us

MULTI-GAS (optional)

There are 3 variations available for this module:

Masimo Phaisen Mainstream IRMA AX+ (without O2);
Masimo Phaisen Sidestream ISA AX+ (without O2);
Masimo Phaisen Sidestream ISA OR+ (with O2);
Masimo Phaisen Sidestream ISA OR+ with O2 for other versions contact us or download the user manual

Gas:CO2,N2O,HAL,ISO,ENF,SEV,DES with automatic identification

Warm-up time: Full accuracy within 20 seconds for IRMA AX+ CO2 Accuracy: 0-10%:±(0.2%+2% of the reading)

0-15%:±(0.3%+2% of the reading)

N2O Accuracy: 0-100%:±(2%+2% of the reading)

HAL,ISO,ENF: 0-8%:±(0.15%+5% of the reading)

SEV:0-10%: ±(0.15%+5% of the reading)

DES:0-22%: ±(0.15%+5% of the reading)

Agent identification time:<20s(typical<10s)

AWRR range: 0-150bpm

AWRR accuracy: +/-1bpm

Apnea time: 20s,25s,30s,35s,40s

BIS (electroencephalogram) (optional)

Type: BISx
Bispectral index (BIS) measurement range: 0 ~ 100
Signal quality index (SQI) measuring range: 0 ~ 100%
Measuring rangeElectromyographic force (EMG): 0 ~ 100dB
Rejection Ratio (SR): 0~100%
Spectral Edge Frequency (SEF): 0.5~30.0HZ
Total paroxysmal (BC): 0~30/min
Noise: • Bandwidth: 0.25~100HZ(-3dB)
Impedance measurement range: 0~999KΩ
NMT (neuromuscular transmission) (optional)

Brand: Tof-Watch
Stimulation modes: TOF (Train Of Four), TOFs (train Of Four) with programmable repetition interval, PTC (Post Tetanic Count), 1 Hz contraction, 0.1 Hz contraction, DBS3.3 and 3.2 (Double Burst), Pacing tetanic (Burst), 5 s. – 50 Hz or 100 Hz
Output (accuracy ±5% of maximum value)
Surface electrodes: Direct current, 0 – 60 mA (0 – 12/18 μC) up to 5 kOhm; Monophasic, 200μs or 300μs pulse duration

Needle electrodes: Direct current, 0 – 6 mA or (0 – 0.24 μC) up to 5 kOhm; Monophasic, 40μs pulse duration

Transducer: acceleration transducer (accuracy ±5% of the maximum value).
Temperature Sensor: range 20.0 – 41.5 °C (accuracy ±0.5 °C)

Data sheet
SEVIG
MNSEV-NOR-000197