High frequency electrosurgical unit that can be used to simultaneously perform monopolar and bipolar surgery.

DOUBLE OPERATIONAL ACTIVITY
- two output channels for monopolar cutting
- two independent calibrations and channels for the most frequent monopolar coagulations

CONTROLLED CUTTING PROCEDURES
- intensified cutting currents for incisions without eschar
- cutting current with coagulating properties for dissection with controlled bleeding
- low capacitive coupling in endoscopic procedures using Slow BLEND current

DOUBLE CONTROLLED COAGULATION PROCEDURES
- SPEEDY coagulation and DEEP coagulation available to 2 operators
- SPRAY coagulation obtainable with handpiece or pedal

BROAD BIPOLAR FEATURES
- bipolar cutting with selectable bleeding control
- slow BLEND cutting currents
- automatic start and stop of coagulation that can be activated separately

TOTAL SAFETY FOR PATIENT AND SURGEON
- acceptability of the contact impedance between the patient's body and the neutral plate continuously verified by the Skin Plate Electronic Control (SPEC)
- continuous monitoring of radio frequency leakage current
- variations in mains voltage automatically compensated before starting the supply of power and radio frequency

CUSTOMIZED PROCEDURES
- independent choice of coagulation currents and power levels of each of the two operators
- ten personal procedures that can be configured and immediately recalled

CONDUCTION OF EXTENSIONS AND CONNECTION SIGNALS
- outputs for piloted connections of argon plasma units and fume extractors

AUTOMATIC SELF-DIAGNOSIS
- automatic diagnostic check of the complete current functionality of the electronic unit and connected accessories and coded indication of the malfunctions found.

- OUTPATIENT SURGERY
- GENERAL SURGERY
- PEDIATRIC SURGERY
- PLASTIC SURGERY
- THORACIC SURGERY
- VASCULAR SURGERY
- DERMATOLOGY
- ENDOSCOPY
- GASTROENTEROLOGY
- GYNECOLOGY
- NEUROSURGERY
- ORTHOPEDICS
- ENT
- PNEUMOLOGY
- UROLOGY
- VETERINARY

1 pc.

Technical features:
- Max pure monopolar CUT cutting power: 300 W - 300 Ohm
- Max monopolar cutting-coag power CUT80%: 250 W - 300 Ohm
- Max monopolar cutting-coag power CUT60%: 200 W - 300 Ohm
- Max monopolar cutting-coag power CUT40%: 150 W - 300 Ohm
- ENHANCED monopolar cutting max power: 200 W - 500 Ohm
- Max monopolar BLEND cutting-coag power: 200 W - 300 Ohm
- SPEEDY monopolar coagulation max power: 100 W - 500 Ohm
- DEEP monopolar coagulation max power: 100 W - 200 Ohm
- Max SPRAY monopolar coagulation power: 70 W - 2000 Ohm
- Max monopolar coagulation power SPRAY ARGON: 70 W - 2000 Ohm
- Max bipolar cutting power CUT: 95 W - 150 Ohm
- Max bipolar cutting-coag cutting power CUT80%: 95 W - 150 Ohm
- Max bipolar cutting-coag cutting power CUT60%: 95 W - 150 Ohm
- Max bipolar cutting-coag cutting power CUT40%: 60 W - 150 Ohm
- Max bipolar cutting-coag power BLEND: 90 W - 150 Ohm
- COAG bipolar coagulation max power: 70 W - 100 Ohm
- Monopolar/bipolar working frequency: 425 kHz / 525 kHz
- Neutral electrode: F
- Selectable power supply: 115-230 Vac
- Mains frequency: 50-60 Hz
- Maximum absorbed power: 1000 VA
- Dimensions WxHxD: 470 x 150 x 400 mm
- Weight 17.5 kg
- Controls: OC plate/patient circuit control, emitted power control, self-diagnosis
- Safety: EN60601-1, EN60601-1-2, EN60601-2-2
- Electrical Class: I CF, MDD 93/42/EC Class: II b

Equipment:
1 - 5 m power cable
1 - Autoclavable handpiece with two buttons (30536)
5 - Sterile handpiece cold with two buttons (30551)
1 - Plate cable (30559)
5 - Rem disposable plates (30493)
2 - HP double watertight pedal set
3 - Short blade electrode 7 cm
3 - Blade electrode 16 cm long
3 - Short ball electrode Ø 4 mm, 6 cm
1 - Electrode cleaning sponge
1 - User manual (IT, GB)
1 - Service manual (IT, GB)