Secure payments
by credit card, Paypal and bank transfer.
by credit card, Paypal and bank transfer.
Fast shipping
with BRT, DPD and FedEx couriers
with BRT, DPD and FedEx couriers
Customer service
via Whatsapp + 39.371.43.61.201
via Whatsapp + 39.371.43.61.201
Description
K15 TOUCHSCREEN 15" MULTIPARAMETRIC MONITOR
Multifunctional monitor to monitor the vital physiological signs of adult, pediatric and neonatal patients.
With real-time recording and display functions of parameters such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it enables analysis complete assessment of the patient's physiological conditions.
- ergonomic design with intuitive user interface
- USB socket for data transfer and software updating
- 9 tracks on video waveforms
- viewing in Windows environment, easy to manage
- visual and audible alarm for physiological and technical anomalies
- large memory capacity
- suitable for use with original Nellcor sensors
- protection against defibrillator discharges, resistance against interference from electrosurgical units; detection and inhibition of cardiac pacemaker impulses
Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU.
PC software only GB.
Technical features:
ECG
- Input dynamic range: ±(0.5~5 mVp)
- Differential input impedance: =10 MO
- Bandwidth:
- 0.05~150 Hz (Diagnostics)
- 0.5~40 Hz (Monitoring)
- 1~20 Hz (Operation)
- CMRR:
- =90 dB (Diagnostics)
- =105 dB (Monitoring & Operation)
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
- Scanning speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater
- Pacemaker pulse detection and inhibition function
RESP
- Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater
TEMP
- Measuring range: 21.0~50.0 °C ±0.2 °C between 25~45 °C
NIBP
- Technique: Oscillometric method
- Typical measurement time: - NIBP SYS measurement range:
- 40~275 mmHg (Adults)
- 40~200 mmHg (Pediatric)
- 40~135 mmHg (Newborns)
- NIBP DIA measurement range:
- 10~210 mmHg (Adults)
- 10~150 mmHg (Pediatric)
- 10~95 mmHg (Newborns)
NIBP MAP measurement range:
- 20~230 mmHg (Adults)
- 20~165 mmHg (Pediatric)
- 20~110 mmHg (Newborns)
- NIBP measurement accuracy:
- Average difference: ±5 mmHg
- Standard deviation: 8 mmHg
- Measurement mode NIBP: Manual, Auto, STAT, Multicycle
- Self-measurement intervals: 1-480 min
SpO2
- Technique: Dual wavelength optical method
- Measuring range: 0%~100% ±2% for SpO2 range 70~100%
- PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater
- Low perfusion efficiency: Up to 0.3%.
CO2
- Technique: Infrared optical method
- Sampling mode: Sidestream or Mainstream
- Measuring range: 0~150 mmHg
- Measurement accuracy:
- 0~40 mmHg ±2 mmHg
- 41~70 mmHg ±5% of reading
- 71~100 mmHg ±8% of reading
- 101~150 mmHg ±10% of reading
- Flow rate: 50 ml/min ±10 ml/min (Sidestream)
Other characteristics
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA
- Built-in lithium battery: 11.1V/4400 mAh
- Screen: 15 inch TFT screen
- Alarm method: 3-level audible-visual alarm
- Network: Ethernet
- Safety standard: IEC 60601-1
- BD/RDM: 1977794
- CND: Z1203020202
- ean13: 8023279353099
- GMDN: 33586
Equipment:
- Adult SpO2 probe
- Adult NIBP cuff
- SpO2 extension cable
- ECG cable
- Skin temperature probe
- Power cord
- Rechargeable lithium battery
- Dust cover
- Disposable electrode
- Manual: GB, FR, IT, ES, PL, RU
Multifunctional monitor to monitor the vital physiological signs of adult, pediatric and neonatal patients.
With real-time recording and display functions of parameters such as ECG, heart rate (HR), non-invasive blood pressure (NIBP), oxygen saturation (SpO2), respiration (RESP), temperature (TEMP), it enables analysis complete assessment of the patient's physiological conditions.
- ergonomic design with intuitive user interface
- USB socket for data transfer and software updating
- 9 tracks on video waveforms
- viewing in Windows environment, easy to manage
- visual and audible alarm for physiological and technical anomalies
- large memory capacity
- suitable for use with original Nellcor sensors
- protection against defibrillator discharges, resistance against interference from electrosurgical units; detection and inhibition of cardiac pacemaker impulses
Internal software: GB, DE, FR, PT, ES, IT, PL, TR, RU.
PC software only GB.
Technical features:
ECG
- Input dynamic range: ±(0.5~5 mVp)
- Differential input impedance: =10 MO
- Bandwidth:
- 0.05~150 Hz (Diagnostics)
- 0.5~40 Hz (Monitoring)
- 1~20 Hz (Operation)
- CMRR:
- =90 dB (Diagnostics)
- =105 dB (Monitoring & Operation)
- Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
- Scanning speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- HR measurement range: 15~350 bpm ±1% or ±2 bpm, whichever is greater
- Pacemaker pulse detection and inhibition function
RESP
- Measuring range: 0~120 rpm ±5% or ±2 rpm, whichever is greater
TEMP
- Measuring range: 21.0~50.0 °C ±0.2 °C between 25~45 °C
NIBP
- Technique: Oscillometric method
- Typical measurement time: - NIBP SYS measurement range:
- 40~275 mmHg (Adults)
- 40~200 mmHg (Pediatric)
- 40~135 mmHg (Newborns)
- NIBP DIA measurement range:
- 10~210 mmHg (Adults)
- 10~150 mmHg (Pediatric)
- 10~95 mmHg (Newborns)
NIBP MAP measurement range:
- 20~230 mmHg (Adults)
- 20~165 mmHg (Pediatric)
- 20~110 mmHg (Newborns)
- NIBP measurement accuracy:
- Average difference: ±5 mmHg
- Standard deviation: 8 mmHg
- Measurement mode NIBP: Manual, Auto, STAT, Multicycle
- Self-measurement intervals: 1-480 min
SpO2
- Technique: Dual wavelength optical method
- Measuring range: 0%~100% ±2% for SpO2 range 70~100%
- PR measurement range: 30~250bpm ±2bpm or ±2%, whichever is greater
- Low perfusion efficiency: Up to 0.3%.
CO2
- Technique: Infrared optical method
- Sampling mode: Sidestream or Mainstream
- Measuring range: 0~150 mmHg
- Measurement accuracy:
- 0~40 mmHg ±2 mmHg
- 41~70 mmHg ±5% of reading
- 71~100 mmHg ±8% of reading
- 101~150 mmHg ±10% of reading
- Flow rate: 50 ml/min ±10 ml/min (Sidestream)
Other characteristics
- Power supply: AC 100-240 V, 50/60 Hz, 60 VA
- Built-in lithium battery: 11.1V/4400 mAh
- Screen: 15 inch TFT screen
- Alarm method: 3-level audible-visual alarm
- Network: Ethernet
- Safety standard: IEC 60601-1
- BD/RDM: 1977794
- CND: Z1203020202
- ean13: 8023279353099
- GMDN: 33586
Equipment:
- Adult SpO2 probe
- Adult NIBP cuff
- SpO2 extension cable
- ECG cable
- Skin temperature probe
- Power cord
- Rechargeable lithium battery
- Dust cover
- Disposable electrode
- Manual: GB, FR, IT, ES, PL, RU
Data sheet
16 other products in the same category: